Customer NameSite AddressMachine Model and Sr numType of visitService VisitAMCCommissioningTrouble shootingCustomer contact PersonCustomer Email AddressThermax Engineer NameEmail AddressNumber of days SpentDay 1 DateHours SpentHours-000102030405060708091011121314151617181920212223Minutes-000102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859Day 2 DateHours SpentHours-000102030405060708091011121314151617181920212223Minutes-000102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859Day 3 DateHours spentHours-000102030405060708091011121314151617181920212223Minutes-000102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859Day 4 DateHours spentHours-000102030405060708091011121314151617181920212223Minutes-000102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859Day 5 DateHours spentHours-000102030405060708091011121314151617181920212223Minutes-000102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859Machine Running HoursPurge pump Running HoursWork environment safe ?OkNot okEquipment and tools suitable for the works?OkNot okPPE available : good condition/trainingOkNot okRAMS reflect the site conditions?OkNot okSD card data collected from machine.YesNoExtra to quoteYesNoObservation Made during the visitWork done during the visitRecommendation to customerUpload PhotosDrag and Drop (or) Choose FilesUpload site photosInstallationIndoorOutdoorFoundationOk As per drawingNot OkLevelingCheckedNot CheckedFlushingDoneNot DonePipingOk, As per DrawingNot As per DrawingCooling water Diverting valveInstalledNot InstalledCooling water/Steam Shut of valveInstalledNot InstalledStrainers in all three circuits as per P&IInstalledNot InstalledPower earth & Instrument earthInstalledNot InstalledN2 pressure in machine /On arrival (bar g)Vacuum hold test (mmHg/hour)LiBr Quantity charged (Kg)Refrigerant Quantity charged (Kg)Moly Quantity charged (Ltr)Octyl Alcohol charged (Ltr)Hot Degreasing after charging molyDoneNot DoneRefrigerant pump Direction and CurrentDirection CheckedDirection not CheckedAbsorbent pump Direction and CurrentDirection CheckedDirection not CheckedPurge pump Direction and CurrentDirection CheckedDirection not CheckedChilled water pump InterlockDoneNot DoneChilled water pump Start/stop permissiveDoneNot DoneCooling water pump InterlockDoneNot DoneCooling water pump Start/stop permissiveDoneNot DoneHot water pump InterlockDoneNot DoneHot water pump Start/stop permissiveDoneNot DoneCooling Tower Fan Start/stop permissiveDoneNot DoneHot water control valve 4-20 mA signal direct connectionDoneNot DoneEwon configuration with TEL accountDoneNot DoneModbus/Profibus connectionDoneNot DoneHealth and Safety checked ?yesnoChilled water pump InterlockCheckedNot CheckedChilled water flow switchCheckedNot CheckedChilled water DP switch/ transmitterCheckedNot CheckedExternal antifreeze thermostat Stp/hystCheckedNot CheckedChilled water PID setpointCheckedNot CheckedChilled water mixing valve Lo-Hi StpCheckedNot CheckedLcut-Hcut Stp/hystCheckedNot CheckedInternal antifreeze Stp/hystCheckedNot CheckedCooling water interlock testCheckedNot CheckedCooling water flow switchCheckedNot CheckedNot availableCooling water DP switch/ transmitterCheckedNot CheckedNot availableCooling tower fan Stp/hystCheckedNot CheckedCooling water diverting valve Lo-Hi StpCheckedNot CheckedCooling water pump AC drive Lo-Hi StpCheckedNot CheckedHP generator trip Stp/hystCheckedNot CheckedLP generator trip Stp/hystCheckedNot CheckedHP generator Diiferential Stp/hystCheckedNot CheckedLP generator Differential Stp/hystCheckedNot CheckedLP/HP Absorbent pump Lo-Hi modulationCheckedNot CheckedHigh concentration Stp/hystCheckedNot CheckedAutoblowdown valve interval/ durationCheckedNot CheckedDamper/ Steam/ HW control valve opening limitCheckedNot CheckedCommunicationCheckedNot CheckedModbus setting: address/bauds/parityCheckedNot CheckedNumber of Readings takenReading 1 DateReading 1 TimeHours-000102030405060708091011121314151617181920212223Minutes-000102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859Purge tank Rise in 2 HrsVacuumChilled water In TemperatureChilled water Out TemperatureChilled water Flow rate/DPCooling water In TemperatureCoolingwater Out TemperatureCooling water Flow/DPHot water In TemperatureHot water Out TemperatureHot water Flow rate/DPHP Generator TemperatureLP Generator TemperatureSpray solution TemperatureDilute TemperatureU tube TemperatureSpray solution ConcentrationAbsorber LevelGenerator LevelEvaporator LevelReading 2 DateReading 2 TimeHours-000102030405060708091011121314151617181920212223Minutes-000102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859Chilled water In TemperatureChilled water Out TemperatureChilled water Flow rate/DPCooling water In TemperatureCooling water Out TemperatureCooling water Flow/DPHot water In TemperatureHot water Out TemperatureHot water Flow rate/DPHP Generator TemperatureLP Generator TemperatureSpray solution TemperatureDilute TemperatureU Tube TemperatureSpray solution ConcentrationAbsorber LevelGenerator LevelEvaporator LevelReading 3 DateReading 3 TimeHours-000102030405060708091011121314151617181920212223Minutes-000102030405060708091011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859Chilled water In TemperatureChilled water Out TemperatureChilled water Flow rate/DPCooling water In TemperatureCooling water Out TemperatureCooling water Flow/DPHot water In TemperatureHot water Out TemperatureHot water Flow rate/DPHP Generator TemperatureLP Generator TemperatureSpray solution TemperatureDilute TemperatureU tube TemperatureSpray solution ConcentrationAbsorber LevelGenerator LevelEvaporator LevelDownload your Report